GD 10 to 40 Amps AC SSR
GD Series Solid State Relays are AC relays,Triac Output. The triac version of the zero switching relay is an inexpensive solution for resistive loads. The zero switching relay switches on when the AC sine voltage just crosses zero,and switches off when the current crosses zero.
·Rated operational current 10 to 40 Amps.
·Rated operational voltage 240V or 440 V
·Input Voltage Range 4 to 16 Vdc,3 to 32 Vdc or 90 to 250 Vac.
·4000 Vrms Optical Isolation.(input/output)
·Both "Zero Voltage" & phase controllable "Random Switching" versions.
·LED-indication for control input.
Selection guide
| Voltage | Control voltage | Rated operational current | |||
| 10 Amp | 15 Amp | 25 Amp | 40 Amp | ||
| 240 VAC "Z" | 4 to 16 Vdc | GD1024ZD1 | GD1524ZD1 | GD2524ZD1 | GD4024ZD1 |
| 240 VAC "R" | 4 to 16 Vdc | GD1024RD1 | GD1524RD1 | GD2524RD1 | GD4024RD1 |
| 240 VAC "Z" | 3 to 32 Vdc | GD1024ZD3 | GD1524ZD3 | GD2524ZD3 | GD4024ZD3 |
| 240 VAC "R" | 3 to 32 Vdc | GD1024RD3 | GD1524RD3 | GD2524RD3 | GD4024RD3 |
| 240 VAC "Z" | 90 to 250Vac | GD1024ZA2 | GD4024ZA2 | GD4024ZA2 | GD4024ZA2 |
| 240 VAC "R" | 90 to 250Vac | GD1024RA2 | GD4024RA2 | GD4024RA2 | GD4024RA2 |
| 440 VAC "Z" | 4 to 16 Vdc | GD1044ZD1 | GD1544ZD1 | GD2544ZD1 | GD4044ZD1 |
| 440 VAC "R" | 4 to 16 Vdc | GD1044RD1 | GD1544RD1 | GD2544RD1 | GD4044RD1 |
| 440 VAC "Z" | 3 to 32 Vdc | GD1044ZD3 | GD1544ZD3 | GD2544ZD3 | GD4044ZD3 |
| 440 VAC "R" | 3 to 32 Vdc | GD1044RD3 | GD1544RD3 | GD2544RD3 | GD4044RD3 |
| 440 VAC "Z" | 90 to 250Vac | GD1044ZA2 | GD1044ZA2 | GD2544ZA2 | GD4044ZA2 |
| 440 VAC "R" | 90 to 250Vac | GD1044RA2 | GD1044RA2 | GD2544RA2 | GD1044RA2 |
Specifications
| PARAMETER-LIST | Units | Specification Limits | |
| Input Parameter ① | D1 | D3 | A2 |
| Control Voltage Range | 4 to 16Vdc | 3 to 32Vdc | 90 to 250Vac |
| Input Current (Max.) | 7/20 mAdc @=5V/12V | 13/16 mAdc @=5V/12 | 30 MAac @=220V |
| Must Turn On Voltage | 4Vdc | 3 Vdc | 90Vac |
| Must Turn Off Voltage | 1Vdc | 1 Vdc | 10Vac |
| Output Parameter ② | Units | Specification Limits | |||
| Model No. GD | 10 | 15 | 25 | 40 | |
| Load Current Range | Arms | 0.05 to 10 | 0.05 to 15 | 0.05 to 25 | 0.05 to 40 |
| Surge Current, 20 mSec (Max.) | Arms | 85 | 115 | 230 | 400 |
| Load Voltage Range (240V) | Vrms | 24 to 280 | |||
| TRIAC Over voltage(240V) | Vpk | ≥600 | |||
| Load Voltage Range (440V) | Vrms | 44 to 440 | |||
| TRIAC Over voltage(440V) | Vpk | ≥800 | |||
| Thermal Resistance, (Rthjc) | ℃/w | 2.5 | 2.5 | 1.3 | 1.1 |
| Frequency Range | Hz | 47 to 63 | |||
| Off State dv/dt (Min) | V/μsec | 200 | |||
| Off State Leakage Current (Max.) | mArms | ≤8 | |||
| On State Voltage Drop (Max.) | Vrms | 1.6 | |||
| Turn On Time (Max.) "Z" | Cycle | 1/2 | |||
| Turn On Time (Max.) "R" | mSec | 1 | |||
| Turn Off Time (Max.) | Cycle | 1/2 | |||
| Turn Off Time(Max.)"A2" | mSec | 40 | |||
| Coupling Specifications | |||||
| Dielectric (Input/Output) | Vrms | 2500 | |||
| Dielectric (Input-Output/Base) | Vrms | 2500 | |||
| Capacitance | pf | 10 | |||
| General Specifications | |||
| Ambient temperature range: operating or Storage -30℃ to +80℃ | |||
| Weight( typical.): | Case A Aluminum Base plate: 99g; Copper Base plate: 145g | ||
| Case B Aluminum Base plate: 81g; Copper Base plate: 120g | |||
| Base plate: Aluminum or Copper, nickel-plated | |||
| Case Color: Black | |||
| Reverse Voltage (Max.) | 32 Vdc | 32 Vdc | / |
| LED Display | Optional | Optional | Optional |